MAXTECH CORPORATION
EN-4300
NIC Type |
Ethernet |
Network Transfer Rate |
10Mbps |
Data Bus |
32-bit VESA Local Bus |
Topology |
Linear Bus, Star |
Wiring Type |
Unshielded twisted pair (location unidentified) RG-58A/U 50ohm coaxial (location unidentified) |
Boot ROM |
Available (location unidentified) |
Diagram not available
USER CONFIGURABLE SETTINGS | |||
Function |
Label |
Position | |
» |
Jumperless mode |
JP3 |
Pins 1 & 2 closed |
Jumpered mode |
JP3 |
Pins 2 & 3 closed |
BASE I/O ADDRESS SELECTION | |||
Address |
J0 |
J1 |
J2 |
Software |
Closed |
Open |
Open |
240h |
Open |
Closed |
Open |
280h |
Closed |
Closed |
Open |
2C0h |
Open |
Open |
Closed |
300h |
Open |
Open |
Open |
320h |
Closed |
Open |
Closed |
340h |
Open |
Closed |
Closed |
360h |
Closed |
Closed |
Closed |
INTERRUPT SELECTION | |||
IRQ |
J3 |
J4 |
J5 |
2 |
Closed |
Closed |
Open |
3 |
Open |
Open |
Open |
4 |
Closed |
Open |
Open |
5 |
Open |
Closed |
Open |
10 |
Open |
Open |
Closed |
11 |
Closed |
Open |
Closed |
12 |
Open |
Closed |
Closed |
15 |
Closed |
Closed |
Closed |
ROM ADDRESS SELECTION | ||||
Address |
J6 |
J7 |
J8 |
J9 |
Disabled |
Open |
Open |
Open |
Open |
C000h |
Closed |
Open |
Open |
Open |
C400h |
Closed |
Closed |
Open |
Open |
C800h |
Open |
Open |
Closed |
Open |
CC00h |
Closed |
Open |
Closed |
Open |
D000h |
Open |
Closed |
Closed |
Open |
D400h |
Closed |
Closed |
Closed |
Open |
D800h |
Open |
Open |
Open |
Closed |
DC00h |
Closed |
Open |
Open |
Closed |