1 3 0 0 SIEMENS NIXDORF NO MORE PRODUCED Native| Translation ------+-----+-----+----- Form 5.25"/FH Cylinders 1216| | | Capacity form/unform 261/ 310 MB Heads 12| | | Seek time / track 25.0/ 5.0 ms Sector/track 35| | | Controller ESDI Precompensation Cache/Buffer 32 KB FIFO BUFFER Landing Zone Data transfer rate 1.250 MB/S int Bytes/Sector 512 MB/S ext Recording method RLL operating | non-operating -------------+-------------- Supply voltage 5/12 V Temperature *C 10 45 | 3 60 Power: sleep W Humidity % 20 80 | standby W Altitude km | idle W Shock g | seek W Rotation RPM 3524 read/write 30.0 W Acoustic dBA spin-up W ECC Bit MTBF h 40000 Warranty Month Lift/Lock/Park YES Certificates ********************************************************************** L A Y O U T ********************************************************************** SIEMENS MEGAFILE 1200/1300 HANDLING INSTRUCTIONS S26371-K64-V1-X7619 +---------------------------------------------------------+ 1 | +-J12 +--J9--+ J11----1 |XX | +-+ +------+ +-----+ |XX J1 | Terminator Address |XX | |XX | |XX | |XX | |XX | |XX | | | |XX1 | |XX J2 | |XX | |XX | |XX | | | |XX J3 | |XX Power +---------------------------------------------------------+ +----------------------------------+ | | | | | | | +J8 Grounding Connector | | ++ | | J3 J2 1 J1 1 | | XXXXXX XXXXXXxX XXXXXXXXXXXXXXxX | +----------------------------------+ ********************************************************************** J U M P E R S ********************************************************************** SIEMENS MEGAFILE 1200/1300 HANDLING INSTRUCTIONS S26371-K64-V1-X7619 Jumper Setting ============== J11 Address Jumper ------------------ +-------------+ +-------------+ |X o o o o o o| Drive 1 |o X o o o o o| Drive 2 |X o o o o o o| |o X o o o o o| +-------------+ +-------------+ 1 2 3 4 5 6 7 1 2 3 4 5 6 7 +-------------+ +-------------+ |o o X o o o o| Drive 3 |o o o X o o o| Drive 4 |o o X o o o o| |o o o X o o o| +-------------+ +-------------+ 1 2 3 4 5 6 7 1 2 3 4 5 6 7 +-------------+ +-------------+ |o o o o X o o| Drive 5 |o o o o o X o| Drive 6 |o o o o X o o| |o o o o o X o| +-------------+ +-------------+ 1 2 3 4 5 6 7 1 2 3 4 5 6 7 +-------------+ |o o o o o o X| Drive 7 |o o o o o o X| +-------------+ 1 2 3 4 5 6 7 J12 Automatic Spin up jumper (Upper than REV 130) ------------------------------------------------- ON Automatic Spin up OFF Power on Command ********************************************************************** I N S T A L L ********************************************************************** SIEMENS MEGAFILE 1200/1300 HANDLING INSTRUCTIONS S26371-K64-V1-X7619 Notes on Installation ===================== Installation direction ---------------------- PCBA down PCBA left PCBA right +-----------------+ +--+ +--+ | | | +-----+ +-----+ | | | | | | | | | +-+-----------------+-+ | | | | | | +---------------------+ | | | | | | | | | | | | PCBA up | | | | | | +---------------------+ | +-----+ +-----+ | +-+-----------------+-+ +--+ +--+ | | | | +-----------------+ Recommended Cables ------------------ Interface Cable 50 Conductor flat ribbon twisted pair or equivalent Power Cable 18 AWG wire with a 4-pin AMP Mate-N-Lok Connector P/N AMP 1-480424-0 Frame Ground 18 AWG wire with AMP P/N 61761-2 or equivalent Optional Front Panel -------------------- REV 1 to REV 129 No. S26371-H30-V1 (C26371-H30-C4) suitable to (metal shielded) metal plate frame 2 LED, Red = error Green = error REV 130 No. S26371-H30-V2 (C26371-H30-C4) suitable to (plastic panel) metal plate frame 1 LED, Red = drive selected Upper than REV 131 No. S26371-H30-V3 (C26371-H23-C321) suitable to (plastic panel) die cast frame 1 LED, Red = drive selected Cable Interconnection --------------------- +-----------+ +-----------------+ | +---o---Control------------------+J1 Drive 1 | | | | +-------Data------------+J2 | | | | | +-Power---+J3 J8 ... | | | | | | +-----+-----------+ | | | | | +-Frame----+ | | | | | | +-----------------+ |Controller | o----+-------------+----+----+J1 Drive 2 | | | | | +-----------+----+----+J2 | | | | | | o----+----+J3 J8 ... | | | | | | | | +----+------------+ | | | | | | o---------+ | | | | | | | +-----------------+ | | o----+-+-----------+----+----+J1 Drive 3 | | | | | | +---------+----+----+J2 | | +---+Data+ | | o----+----+J3 J8 ... | | +---+-Data-+ | | | +-----+-----------+ | | | | | o----------+ | +---+-Data---+ | | +-----------------+ | | +------------------+----+----+J1 Drive 7 | | +-----Data-------------+----+----+J2 | | | o----+----+J3 J8 XXX | +-----------+ | | +-----+-----------+ DC voltages----+ o----------+ | Frame Ground--------+ ... = Terminator Pack removed XXX = Terminator Pack installed Terminator installed only in the last physical drive in a chain. Max. cable length 3 meters. Screws ------ Mounting Holes 2 per side #6-32 UNC-2B 0.14 (3.5) deep (4x) Mounting Holes 4 on bottom #6-32 UNC-2B, 0.4 (10) deep (4x) NOTE Mounting Holes 2 per side are different in depth to the mounting holes 4 on bottom. J3 DC Power and pin connector assignments ------------------------------------------- pin 1 +12 VDC pin 2 +12 Volts Return pin 3 + 5 Volts Return pin 4 + 5 VDC