1 5 4 8 - 1 5 D MICROPOLIS NO MORE PRODUCED Native| Translation ------+-----+-----+----- Form 5.25"/FH Cylinders 2099| | | Capacity form/unform 1748/ 2000 MB Heads 15| | | Seek time / track 11.0/ 2.5 ms Sector/track | | | Controller SCSI2 DI/FAST Precompensation Cache/Buffer 256 KB DUAL-PORTED Landing Zone Data transfer rate MB/S int Bytes/Sector 512 10.000 MB/S ext SYNC Recording method RLL operating | non-operating -------------+-------------- Supply voltage 5/12 V Temperature *C 10 50 | -40 65 Power: sleep W Humidity % 10 90 | 10 90 standby 18.0 W Altitude km -0.061 3.048| -0.305 15.240 idle W Shock g 3 | 40 seek W Rotation RPM 3600 read/write 24.0 W Acoustic dBA 40 spin-up W ECC Bit 64 MTBF h 150000 Warranty Month 60 Lift/Lock/Park YES Certificates ********************************************************************** L A Y O U T ********************************************************************** MICROPL. 1548 PRODUCT DESCRIPTION 110682 REV. B Single-Ended +---------------------------------------------------------++-+ | || 20 J2 | || | | COMPONENT SIDE || | ID2 | || | ID1 | W8 ++ |1-2 ID0 | || W12+++ |XX | W9 ++ +++ |XX | RN6+-+ |XX | Interface | | |XX | Terminator| | |XX J1 | | | |XX | +-+ |XX | ++++ |XX | ++++ |XX | W2 W1 | 1 | Frame Ground W11++ |XX J3 | ++ |XX Power +---------------------------------------------------------+ 1 Differential +---------------------------------------------------------++-+ | || 20 J2 | || | | COMPONENT SIDE +-+ || | ID2 | RN12 | || | ID1 | W8 ++ | | |1-2 ID0 | || | | |XX | W9 ++ +-+ |XX | W2++++W1|XX | ++++ |XX | W10+++ |XX J1 | +++ |XX | RN11-+ |XX | | | |XX | | | |XX | | | | 1 | Frame Ground W11++ +-+ |XX J3 | ++ |XX Power +---------------------------------------------------------+ 1 +--------------------------------------+ | ++J4 HDA Ground Connector | | ++ | | ++J5 Frame Ground Connector | | ++ | | | | J2 1 J1 1 J3 1| +..........-XXXXXXXXXXXXXXXXXX-XXXXXXXX+ +-Multi-+++---Signal------------Power--+ ||| ||+--- SCSI ID0 |+---- SCSI ID1 +----- SCSI ID2 ********************************************************************** J U M P E R S ********************************************************************** MICROPL. 1548 PRODUCT DESCRIPTION 110682 REV. B Jumper Setting ============== x = Jumpers setting at factory J2 Multi-Function Connector ---------------------------- Write Protect Option----+ +---------Spindle Control Option | | +------ID2 Bus Parity Check Option--+ | | | +---ID1 | | | | | ID0 --+ +--+--+--+--+--++-++-+--++-++-++-+-++ +----- +--+23|21|19|17|15|13|11|09|07|05|03|01+-+ +--+24|22|20|18|16|14|12|10|08|06|04|02+-+ J1 --+ +--+--+-++--++-+--+--+--+--+--+--+--+ +------ Slave Sync+ Master Sync Note: Pins 2, 4, 6, 8, 10, 12, and 14 are tied to Ground. J2 SCSI ID ----------- +----------+-----------------------+ | SCSI ID | Jumpers | | | ID2 | ID1 | ID0 | +----------+-------+-------+-------+ |x 0 | OPEN | OPEN | OPEN | | 1 | OPEN | OPEN | CLOSED| | 2 | OPEN | CLOSED| OPEN | | 3 | OPEN | CLOSED| CLOSED| | 4 | CLOSED| OPEN | OPEN | | 5 | CLOSED| OPEN | CLOSED| | 6 | CLOSED| CLOSED| OPEN | | 7 | CLOSED| CLOSED| CLOSED| +----------+-------+-------+-------+ Up to eight devices (the host and seven targets) can be attached to the SCSI bus. The 1548 drive has three ID jumpers. These three jumpers are used to assign one of the eigth SCSI ID bits (0 through 7) to the drive. SCSI ID = 0; factory default configuration. In multiple-device systems, each drive must have its own unique ID bit. Single-Ended Interface Terminator RN6 provides proper termination for the inter- face lines. For a multiple-drive system, the terminator is installed in the last drive on the cable. Differential Interface Terminator packs RN11 and RN12 provide proper termination for the interface lines. For a multiple-drive system, the terminators are installed in the last drive on the cable. J2 Spindle Control Option -------------------------- Pin 7-8 CLOSED The drive must wait for an interface START UNIT command to start the spindle motor. OPEN The drive automatically starts the spindle motor at power-on. (Factory default configuration) J2 Write Protect Option ------------------------ Pin 11-12 CLOSED The drive is write protected. CAUTION: The drive can still be formatted. OPEN The drive is not write protected. (Factory default configuration) J2 Bus Parity Check Option --------------------------- Pin 13-14 CLOSED The drive neither generates nor detects parity. OPEN The drive generates parity and enables parity detection. (Factory default configuration) J4/J5 Ground Connectors ------------------------ 3/16-inch spade lugs J4 and J5 are provided for grounding. System characteristics determine proper ground connection. W1/W2/W12 Bus Termination Power Option (Single-Ended) ------------------------------------------------------ +-----------------------+------------------------------------+ | Jumpers | | | W1 | W2 | W12 | | +-------+-------+-------+------------------------------------+ | CLOSED| OPEN | OPEN |The drive provides terminator power | | | | |to its on-board terminators | | | | |(Factory default configuration) | +-------+-------+-------+------------------------------------+ | OPEN | CLOSED| OPEN |Terminator power is provided by the | | | | |host via interface cable J1, pin 26 | +-------+-------+-------+------------------------------------+ | OPEN | CLOSED| CLOSED|The drive provides terminator power | | | | |to its on-board terminators and | | | | |also to the SCSI bus via interface | | | | |cable J1, pin 26 (TERMPWR) | +-------+-------+-------+------------------------------------+ A jumper is installed at W1, at W2, or at W2 and W12 to select the source of terminator power (+5V) for the SCSI bus terminator packs on the Device Electronics board. Do not install jumpers at both W1 and W12. W1/W2/W10 Bus Termination Power Option (Differential) ------------------------------------------------------ +-----------------------+------------------------------------+ | Jumpers | | | W1 | W2 | W10 | | +-------+-------+-------+------------------------------------+ | CLOSED| OPEN | OPEN |The drive provides terminator power | | | | |to its on-board terminators | | | | |(Factory default configuration) | +-------+-------+-------+------------------------------------+ | OPEN | CLOSED| OPEN |Terminator power is provided by the | | | | |host via interface cable J1, pin 26 | +-------+-------+-------+------------------------------------+ | OPEN | CLOSED| CLOSED|The drive provides terminator power | | | | |to its on-board terminators and | | | | |also to the SCSI bus via interface | | | | |cable J1, pin 26 (TERMPWR) | +-------+-------+-------+------------------------------------+ A jumper is installed at W1, at W2, or at W2 and W10 to select the source of terminator power (+5V) for the SCSI bus terminator packs on the Device Electronics board. Do not install jumpers at both W1 and W10. W8/9 Spindle Synchronization Option ------------------------------------ Jumpers installed (CLOSED) at W8 and W9 provide termination for the Spindle Synchronization signals (Slave Sync and Master Sync respect- ively). When the Spindle Synchronization option is to be implemented, the jumpers are removed from all drives except the last drive on the cable. The Rotational Position Locking field (MODE SELECT command, Page Code 04h) is used to specify spindle synchronization operation. The following options are supported: Unsynchronized: If the drive is set to Unsynchronized (RPL = 00b), it ignores the SLAVE SYNC signal. Slave: If the drive is set to Slave (RPL = 01b), it does not generate the MASTER SYNC signal or the SLAVE SYNC signal but synchronizes its index to the SLAVE SYNC signal (J2, pin 20) supplied by an external source. Master: If the drive is set to Master (RPL = 10b), it generates the SLAVE SYNC output signal (J2, pin 20) for use directly by the slave drives. Master Control: If the drive is set to Master Control (RPL = 11b), it generates the MASTER SYNC signal (J2, pin 16). This output is used by the controller to generate the SLAVE SYNC signal (J2, pin 20) for the slaves. W11 Frame Ground Option ------------------------ W11 CLOSED Frame ground is connected to logic ground OPEN Frame ground is not connected to logic ground (Factory default configuration) J3 DC Power and pin connector assignments ------------------------------------------- +------------+ pin 1 +12 V | 1 2 3 4 | pin 2 +12 V Return +------------+ pin 3 + 5 V Return pin 4 + 5 V ********************************************************************** I N S T A L L ********************************************************************** MICROPL. 1548 PRODUCT DESCRIPTION 110682 REV. B Notes on installation ===================== Drive mounting -------------- horizontally vertically +-----------------+ +--+ +--+ +------------------+ | | | +-----+ +-----+ | | | x | | | | | | | | x+----------------+x +-+-----------------+-+ | | | | | | ||x x|| +---------------------+ | | | | | | || x x || | | | | | | || x x || x x | | | | | | || x x || +------x------x-------+ | +-----+ +-----+ | || xx || +-+------x--x-------+-+ +--+ +--+ || x x || | xx | || x x || | x x | || x x || +---x--------x----+ |x x| x x x++----------------++x Dimensions and Mounting ----------------------- The 1548 drive uses industry-standard mounting techniques for 5 -inch full-height Winchester disk drives. Recommended orientation is vertical on either side, or horizontal with the Device Electronics board down; other mounting orientations may be used provided the ambient air temperature around the drive is kept at or below 50*C (122*F). The term "ambient" becomes imprecise when referencing a drive in a system, since it is difficult to determine where the air temperature should be measured. To help resolve this confusion, Micropolis specifies that the maximum HDA casting temperature (regardless of the air temperature around the drive) is 60*C (140*F). Not exceeding this temperature will ensure that the head-to-media interface never exceed its temperature limit. Mounting Screws --------------- 2 per side 6-32 UNC-2B 4 on bottom 6-32 UNC-2B Caution: The mounting screws must be selected so that they do not penetrate the bottom mounting holes by more than 0.20 inches or the side mounting holes by more than 0.156 inches. Screws that are too long will short to PCBA components and/or prevent proper operation of the shock mount system. SINGLE-ENDED Interface Electrical Characteristics ------------------------------------------------- Interface control and status signals are digital (open collector TTL) using industry-standard transmitters and receivers which provide a terminated, single-ended system. The assigned signals are terminated with 220 ohms to +5V (nominal) and 330 ohms to ground at each end of the cable. All signals use open-collector or three-state drivers. Single-ended drivers and receivers allow a maximum cable length of six meters (primarily for connection within a cabinet). Signal transmission requires a single 50-conductor cable. A characteristic impedance of 100 ( 10%) ohms is recommended for un- shielded flat or twisted pair ribbon cable. a. Input Characteristics Each of the drive's signal receivers has the following characteristics when measured at the interface connector. 1) Signal true = 0.0 VDC to 0.8 VDC 2) Maximum total input load = -0.4 milliamps at 0.5 VDC 3) Signal false = 2.0 VDC to 5.25 VDC 4) Minimum input hysteresis = 0.2 VDC b. Output Characteristics Each driven signal has the following characteristics when measured at the interface connector. 1) Signal assertion = 0.0 VDC to 0.5 VDC 2) Minimum driver output capability = 48 milliamps (sinking) at 0.5 VDC. 3) Signal negation = 2.5 VDC to 5.25 VDC c. Terminator Power (TERMPWR at Pin 26) Terminator Power has the following requirements: V(TERM) = 4.25 VDC to 5.25 VDC 800 milliamps minimum source drive capability, with 1.0 amp recommended current limiting (e.g., a fuse). 1.0-milliamp maximum bus loading (except for the purposes of providing power to an internal terminator). The 1548 disk drive provides keyed connectors to prevent accidental grounding or misconnection of terminator power. DIFFERENTIAL Interface Electrical Characteristics ------------------------------------------------- Differential interface signals consist of two signal lines which are denoted +SIGNAL and -SIGNAL. A signal is defined as true when the +SIGNAL is more positive than the -SIGNAL. A signal is defined as false when the -SIGNAL is more positive than the +SIGNAL. Differential drivers and receivers allow a maximum cable length of 25 meters. Signal transmission requires a single 50-conductor cable. A characteristic impedance of 100 ( 10%) ohms is recommended for un- shielded flat or twisted-pair ribbon cable. A minimum conductor size of 28 AWG should be employed to minimize noise effects and ensure proper distribution of optional terminator power. A stub length of no more than 0.2 meters is allowed off the main-line interconnection within any connected equipment. a. Input Characteristics Each of the drives signal receivers has the following characteristics when measured at the interface connector. I (input current on either input) = 2.0 milliamps, maximum Note: These characteristics include both receivers and passive drivers. This requirement is met with the input voltage varying between -7V and +12V, with power either on or off, and with hysteresis equaling 35 millivolts, minimum. b. Output Characteristics Each driven signal has the following characteristics when measured at the interface connector. VOL (low-level output voltage) = 1.7V maximum at IOL where IOL = 55 milliamps VOH (high-level output voltage) = 2.7V maximum at IOH where IOH = -55 milliamps VOD (differential voltage) = 1.0V minimum, with common-mode voltage ranges from -7 to +12 VOL and VOH are measured between the output terminal and the SCSI device's logic ground reference. c. Terminator Power (TERMPWR at Pins 25 and 26) Terminator Power has the following requirements: V(TERM) = 4.0 VDC to 5.25 VDC 600 milliamps minimum source drive capability, with 1.0 amp recommended current limiting (e.g., a fuse). 1.0-milliamp maximum bus loading (except for the purposes of providing power to an internal terminator). The 1548D drive provides keyed connectors to prevent accidental grounding or misconnection of terminator power. Interface Terminator packs RN11 and RN12 provide proper termination for the differential interface lines. Signal Connector J1 ------------------- J1 is a 50-pin connector. Signal interface connection is made via this connector. The signals on J1 include the 8-bit SCSI bus and various control and handshaking lines. Recommended Cable: 3M Scotchflex 3365/50 or equivalent. Mating connector: 3M P/N 3425-3000 or equivalent. J2 Multi-Function Connector/Jumper Block ---------------------------------------- J2 is a 24-pin, multi-function connector/jumper block. J3 DC Power Connector ---------------------- J3 is a 4-pin, keyed, AMP MATE-N-LOCK connector. Both +5V and +12V are supplied to the drive via this connector. Mating Connector: AMP 1-480424-0 or equivalent Pins: AMP 350078-4 Suggested Wire Size: 18 AWG Ground Connectors J4 and J5 --------------------------- 3/16-inch spade lugs J4 and J5 are provided for grounding. Systems characteristics determine proper ground connection. Mating connector: AMP 60972-2 or equivalent. Multiple-Drive Systems ---------------------- Up to seven 1548 drives can be connected to a single host. Drive #1 +------HOST------+ +-----------------+ | +-----------+ +--+-SCSI-BUS-----+ J1 | | |Terminators| | | +------+ J3 J4/J5 | | +-----------+ | | | +--------+--------+ | | | | +------------------+ +----------------+ | | Drive #2 | | | +-----------------+ | +-------+------+ J1 | | | o------+ J3 J4/J5 | | | | +--------+--------+ | | | +------------------o | | Drive #3 | | | +-----------------+ | +-------+------+ J1 | | | o------+ J3 J4/J5 | | | | +--------+--------+ | | | +------------------o | | Drive #4 | | | +--------------+--+ | +-------+------+ J1 |T | | o------+ J3 J4/J5 +--+ | --DC-Voltages------+ +--------+--------+ | ---GROUND--------------------------o------------------+ T = TERMINATORS Terminators are installed ONLY in the last physical drive in the control chain. Connectors J4 and J5 are provided for grounding; system character- istics determine the proper ground connection. Adjustments and Maintenance --------------------------- The 1548 drives requires no adjustments or periodic maintenance; additionally, no mechanical adjustments are required to prepare a system for handling or shipment. Field-Replacable Components --------------------------- The concept of repair by replacement of complete functional components is utilized in the 1548, resulting in an MTTR of less than 15 minutes. Air Filtration System --------------------- The 1548 drives are designed to provide contamination control within the sealed HDA throughout the life of the drive with zero maintenance. Air within the HDA is continuously recirculated and filtered through a high efficiency filter. Air is ducted to and from the filter for maximum pressure recovery and filter efficiency. Air within the HDA may only enter the drive through a high-efficiency breather filter. ********************************************************************** F E A T U R E S ********************************************************************** MICROPL. 1548 PRODUCT DESCRIPTION 110682 REV. B Micropolis 1548S (single-ended) and 1548D (differential) high- performance, 5 -inch full-height Rigid Disk Drives provide OEMs with random-access, high-speed data storage and meet the needs of diverse applications environment. These drivers are compatible with the "ANSI CCS" and "SCSI-2" versions of the industry-standard Small Computer System Interface (SCSI) specification. Throughout this Product Description the term "1548 drive" or "1548" refers to characteristics common to both the single-ended and differential drives. Some Features of the Drive -------------------------- Programmable sector sizes from 180 to 4096 bytes in 1-byte in- crements. Automatic error recovery. Performance is enhanced by low SCSI command overhead. Intelligent features such as read-ahead and sophisticated buffer management make maximum use of the 256K dual-ported data buffer, which has full parity for data integrity. Media Defects ------------- Media defects are physical characteristics of the media which result in repetitive read errors when a functional drive is operated within specified operating conditions. At the time of manufacture, a media test system evaluates every drive and identifies each media defect location. The defective areas are identified by head address (HD), cylinder address (CYL), and number of bytes from Index (BFI). The list of manufacturer-found defects is stored on the drive in a reserved, write-protected area accessible by the SCSI controller. This list is known as the MDL (Manufacturers Defect List) or PList (Primary Defect List). A printed listing of the defects is also shipped with each drive. The entries it contains can be mapped out (reassigned) automatically at format time by appropriate use of the format control parameter bits. Seek Time --------- | 1548 | ----------------------------------+--------+ Adjacent Track msec. | 2.5 | ----------------------------------+--------+ Average msec. | 14 | ----------------------------------+--------+ Full Stroke msec. | 29 | ----------------------------------+--------+ One-Third Stroke msec. max. | 14.5 | ----------------------------------+--------+ Latency msec. avg. | 8.33 | ----------------------------------+--------+